With the widespread application of the laparoscopic technology, the complications attacking of the abdominal puncture has been increasing, such as puncture hole hemorrhage, hernia, puncture hole not-well-healed, etc. Among those complications, some ones have serious connections with the closure of the puncture hole, like hemorrhage and hernia.
To prevent the puncture hole hemorrhage and hernia, usually the following procedures are taken to close the puncture hole. With the endoscope a normal medium curved vascular clamp is used to lift the fascia peritoneum and a round leading needle with line is used for closing. As the cut is relatively small and/or the parietal wall is relatively thick and the internal organs are surging up the cut, it is difficult to see the peritoneum and tunica vaginalis, especially for obese patients.
After extensive communications with the surgeons, our research staff have carried on the independent innovations to design a device that can be standardized produced for closing the laparoscopic surgery puncture hole with the advanced ideas both at home and abroad. The device is well designed with smart structure, accurate and easy to use with causing little trauma. With the endoscope monitoring it can suture the parietal wall fast and accurately to reduce hemorrhage and to prevent the hernia. It is believed that the use of the device can assist the laparoscopic surgery effectively.
The product consists of two parts, one called the fascial closure system and the other one called the leading needle. Insert the Fascial Closure System through the port, spread then lock the wings, load one end of the No.0 suture. Pull upwards the pulling ring, get the wings close to the abdominal wall. Insert the leading needle into one guiding channel, pierce the silicon pad then extract the leading needle. Repeat steps 1&2 to send the other end of the suture to the silicon pad. Visually make sure that both suture ends are firmly stuck in the silicon pads. Then close and lock the wings, pull the Fascial Closure System out of the body. Unloading both ends from the silicon pads, make a standard surgical knot to close the target endoscopic port. Under normal operation, a puncture hole can be closed in 2-3 minutes.
● Insert the needle and thread at the same time, tighten up the thread and tie a knot.
● Open and close the wings, finish when hear "click".
● The thread is firmly stuck in the silicon pads.
Reliability
● Needle obliquely penetrates the myofascial and peritoneum of the abdominal wall.
● Needle tip 1cm away from inner abdominal wall after insertion.
● Close the entire abdominal wall myofascial defect to eliminate the hidden danger of hernia.
Flexibility
● Closure of various ports in single surgery.
● Select the appropriate thread according to the type of incision.
Code | Products Description | Length |
---|---|---|
FCS100 | Single Use Fascial Closure System | 100mm |
The device application video shown here is not used as a surgical skill training guide. Doctors can treat differently in different procedures, according to the actual clinical situation, their own clinical experience and use preference,
Before using this demonstrative product, please carefully read the product Instructions for Use, indications and contraindications, check the integrity of all devices and accessories in the package, and use them correctly according to the Instructions for Use, to avoid adverse consequences.