Endo Cutter and Reload is used to cut and suture tissue in open and endoscopic surgeries. The specific application mode is listed as follows:

Firstly, cutting and stapling tissue, such as intestine transection, sleeve-shaped resection of subtotal gastrectomy, gastric bypass surgery, cutting and stapling large vessels or bronchi, cutting lung tissue to make fissure lung, and pulmonary wedge resection.

Secondly, side-to-side anastomosis of digestive tract or functional end-to-end anastomosis, such as side-to-side anastomosis of gastric-jejunum, trigonal anastomosis of gastroduodenal, etc.

Thirdly, closing the incision on GI or the joint incision on GI after side-to-side anastomosis.

GoldenStapler Endo Cutter releases 6 rows of staples when firing, and the cutting line is in the middle of them. Unequally stepped closed staple heights design provides better blood supplying for sutured tissue and better hemostasis for incisal edge, much more conforming to the principle of surgical suturing and hemostasis.

Simplicity
● Thin anvil, fixed to the cartridge reload, can be accessed through a very narrow space below the tissue.
● Cartridge head can be rotated in 45°at both left and right sides, easily adjusted to the appropriate angle to operate.
● Devices without scathing pre-holding force can be multi-used, such as grasping forceps.
● One device is equipped with various cartridge reloads, accommodating to different surgical positions.

Reliability
● Unequally stepped closed staple heights design provides better blood supplying for sutured tissue and better hemostasis for incisal edge.
● Using new cartridge reload each time, in line with the principle of non-tumor.
● When firing, “工” shaped cutting knife is removed from near end to distal end. Closing, cutting, and stapling at the same time, ensuring uniform formation height of all staples of each row.
● Safety device prevents firing the empty cartridge reload.

Flexibility
● Specific cartridge reload is chosen for different tissue with different thickness which ranges from 0.8mm to 2.1mm, such as white one for transecting pulmonary vessels, green one for transecting bronchus.
● Specific cartridge reload is chosen for different positions of same tissue, such as when cutting the stomach to make sleeve gastrectomy, green one for the gastric antrum, green or yellow one for the gastric body, and blue one for the gastric fundus.
Code Products Description Reload Color Staple Rows Suturing Length Closed Staple Height Remark
EC-60-Ⅰ Single Patient Use Endo Cutter, 60-Ⅰ 60mm
EC-160-Ⅰ Single Patient Use Endo Cutter, 160-Ⅰ 160mm
EC-260-Ⅰ Single Patient Use Endo Cutter, 260-Ⅰ 260mm
ECRC30T Single Patient Use Endo Cutter Reload, C30T White 4 30mm 0.8mm-0.8mm Curved Tip
ECRC30W Single Patient Use Endo Cutter Reload, C30W White 6 30mm 0.8mm-1.0mm-1.1mm Curved Tip
ECRC30B Single Patient Use Endo Cutter Reload, C30B Blue 6 30mm 1.3mm-1.5mm-1.6mm Curved Tip
ECRC45W Single Patient Use Endo Cutter Reload, C45W White 6 45mm 0.8mm-1.0mm-1.1mm Curved Tip
ECRC45B Single Patient Use Endo Cutter Reload, C45B Blue 6 45mm 1.3mm-1.5mm-1.6mm Curved Tip
ECRC60B Single Patient Use Endo Cutter Reload, C60B Blue 6 60mm 1.3mm-1.5mm-1.6mm Curved Tip
ECRA45M Single Patient Use Endo Cutter Reload, A45M Grey 6 45mm 0.8mm-0.8mm-0.8mm Customer Made
ECRA45W Single Patient Use Endo Cutter Reload, A45W White 6 45mm 0.8mm-1.0mm-1.1mm Articulation
ECRA45B Single Patient Use Endo Cutter Reload, A45B Blue 6 45mm 1.3mm-1.5mm-1.6mm Articulation
ECRA45Y Single Patient Use Endo Cutter Reload, A45Y Yellow 6 45mm 1.6mm-1.8mm-1.9mm Articulation
ECRA45G Single Patient Use Endo Cutter Reload, A45G Green 6 45mm 1.8mm-2.0mm-2.1mm Articulation
ECRA60M Single Patient Use Endo Cutter Reload, A60M Grey 6 60mm 0.8mm-0.8mm-0.8mm Customer Made
ECRA60W Single Patient Use Endo Cutter Reload, A60W White 6 60mm 0.8mm-1.0mm-1.1mm Articulation
ECRA60B Single Patient Use Endo Cutter Reload, A60B Blue 6 60mm 1.3mm-1.5mm-1.6mm Articulation
ECRA60Y Single Patient Use Endo Cutter Reload, A60Y Yellow 6 60mm 1.6mm-1.8mm-1.9mm Articulation
ECRA60G Single Patient Use Endo Cutter Reload, A60G Green 6 60mm 1.8mm-2.0mm-2.1mm Articulation
ECRB45W Single Patient Use Endo Cutter Reload, B45W White 6 45mm 0.8mm-1.0mm-1.1mm Non-articulation
ECRB45B Single Patient Use Endo Cutter Reload, B45B Blue 6 45mm 1.3mm-1.5mm-1.6mm Non-articulation
ECRB45Y Single Patient Use Endo Cutter Reload, B45Y Yellow 6 45mm 1.6mm-1.8mm-1.9mm Non-articulation
ECRB45G Single Patient Use Endo Cutter Reload, B45G Green 6 45mm 1.8mm-2.0mm-2.1mm Non-articulation
ECRB60W Single Patient Use Endo Cutter Reload, B60W White 6 60mm 0.8mm-1.0mm-1.1mm Non-articulation
ECRB60B Single Patient Use Endo Cutter Reload, B60B Blue 6 60mm 1.3mm-1.5mm-1.6mm Non-articulation
ECRB60Y Single Patient Use Endo Cutter Reload, B60Y Yellow 6 60mm 1.6mm-1.8mm-1.9mm Non-articulation
ECRB60G Single Patient Use Endo Cutter Reload, B60G Green 6 60mm 1.8mm-2.0mm-2.1mm Non-articulation
Articulated Design
Articulated Design Articulated up to 45°left and right
Provide the best angulation for easy surgery
Rotate-to-Connect Design of Device Shaft and Articulated Reload Shaft
Rotate-to-Connect Design of Device Shaft and Articulated Reload Shaft30, 45 & 60mm reloads are available
60mm hand piece can be applied in open surgeries
160mm hand piece in common endo-surgeries
260mm hand piece for obese patients
Shaft can be rotated 360°
Three Lengths of Cartridge Reloads
Three Lengths of Cartridge Reloads 30mm, 45mm, and 60mm
Each length of cartridge reloads contains: white, blue, yellow and green
Suitable for cutting and closing 0.8-2.1mm thickness tissue
12mm trocar is required to pass through from outside into inside of abdominal wall
Replace new cartridge reload after each firing, including staples, anvil, cutting knife, in comply with tumor-free principle
Non-injurious pre-grasping force, being used as forceps, decreases the changing of devices
Less side overflow and end overflow of tissue when firing
Unequally Stepped Closed Staple Height
Unequally Stepped Closed Staple Height Release 6 rows of staples when firing, with knife cutting along the middle of staple rows
Unequal height difference, best balancing between and blood-supply
Fixed Anvil Design
Fixed Anvil Design Thin and fixed anvil could be accessed to narrow tissue space
Provide better vision when closing the tissue
>>
  • Cuting the Splenic Pedicle with 30mm White Endo Cutter Reload
  • Cutting & Stapling Small Intestine
  • Cutting & Stapling Splenic Pedicle 1
  • Cutting & Stapling Splenic Pedicle 2
  • Cutting & Stapling Stomach Tissue 1
  • Cutting & Stapling Stomach Tissue 2
  • Air Leakage Experiment
  • Cutting & Stapling Lung Tissue 1
  • Cutting & Stapling Lung Tissue 2
  • Cutting & Stapling Azygos Vein
  • Cutting & Stapling Pulmonary Artery
  • Air Leakage Experiment in Cutting
  • Cuting the Splenic Pedicle with 45mm White Endo Cutter Reload
  • Cutting the Gastric Tissue with Endo Cutter
  • Cutting Renal Pedicle with Endo Cutter
  • Functional End-to-end Anastomosis with Endo Cutter

The device application video shown here is not used as a surgical skill training guide. Doctors can treat differently in different procedures, according to the actual clinical situation, their own clinical experience and use preference,